The LPT30 is intended for usage as an electrical transfer switch to automatically switch multiple sources (from one to another), i.e. switching from shoreline to generator power or switching from electronic inverter to shoreline/generator.
The LPT30 is primarily designed for installation in conjunction with a generator having a rated output of not larger than 4.5kw, an external power cord having a rated output of not larger than 120VAC, 30A, 1PH, 60HZ and an electronic inverter having a rated output of not larger than 3600 watts.
Contractors: General purpose DPDT 30 amp relay
Coil: 110VDC, 2 watts
Time Delay: Custom time delay, 30 seconds nominal may bypass time delay with switch on board
Physical Size: 6" x 6" x 3"
Knockouts: 1/2" and 3/4"
Cautions: Install vertically or horizontally in a dry, accessible area.*Maximum service 120 VAC, 30AMPS single phase: must be used with a circuit distribution panel having a main breaker rated 30AMPS-1 Pole, or less. Suitable for installation in conjunction with power supplies having rated outputs not larger than 120VAC, 30AMPS.
*Additional shipping costs apply.
120VAC 30 AMPS/POLE
The LPT30BRD is intended for use as an electrical transfer switch to automatically switch multiple sources (from one to another), i.e. switching from shoreline to generator power.
The LPT30BRD is primarily designed for installation in conjunction with a generator having a rated output of no more than 4.5KW and an external power cord having a rated output of no more than
120VAC, 30A, 1PH, 60HZ.
CONTACTORS: General purpose DPDT 30 Amp relayRELAY COIL: 110VDC, 2 Watts
PHYSICAL SIZE: 8 1/2” X 8 1/2” X 4 1/2”KNOCKOUTS: Assorted TIME
DELAY: Custom time delay, 30 seconds nominal. Can be bypassed for instant switching.
WEIGHT: 6.60 lbs
Cautions: install vertically or horizontally in a dry, accessible areamaximum service 120VAC, 30AMPS single phase: must be used with a circuit distribution panel having a main
breaker rated 30amps-1 pole or smallersuitable for installation in conjunction with power supplies having rated outputs no larger than 120VAC, 30AMPS.
*Additional shipping costs apply.
*Additional shipping costs apply.
120VAC-240VAC 50 AMPS/POLE70 AMP NEUTRAL
The LPT50BRD is intended for use as an electrical transfer switch to automatically switch multiple sources (from one to another), i.e. switching from shoreline to generator power.
The LPT50BRD is primarily designed for installation in conjunction with a generator having a rated output of no more than 12KW and an external power cord having a rated output of no more than
240VAC 1PH 60HZ, 2 poles at 50 Amps per pole.
CONTACTORS: General Purpose DPDT 50 Amp relays.
COIL: 110 VDC 2 Watts.
TIME DELAY: Custom time delay, 30 seconds nominal. Can be bypassed for instant switching.
PHYSICAL SIZE: 8 1/2” X 8 1/2” X 4 1/2”
KNOCKOUTS: Assorted.WEIGHT: 7.95 lbs.
CAUTIONS: Install vertically or horizontally in a dry, accessible areaConsult factory before drilling metal caseKeep covered except during wiring as contactors are sensitive
to debrisHi-pot with lpt50brd disconnected or hi-pot on load side of switch.
*Additional shipping costs apply.
*Additional shipping costs apply.
120VAC-240VAC 75 AMPS/POLE90 AMP NEUTRAL
Automatic Transfer Switch
The LPT 75CA is intended for use as an electrical transfer switch to automatically switch multiple sources (from one to another), i.e. switching from shoreline to generator power.
The LPT 75CA is primarily designed for installation in conjunction with a generator having a rated output no larger than 18KW, an external power cord having a rated output no larger than 240 VAC,
2 poles 50A per pole, 1PH, 60HZ.
Contactors: 3 Pole N.O. 240VAC, 75 AMPS/POLECoil: 104-120VAC (60HZ, inrush current - 84 watts, sealed - 8 watts)
Auxiliary switch: shoreline release switch 120VAC, N.C.
Time delay: custom time delay, 30 seconds nominal
Physical size: 12” x 8” x 4” Knockouts: assorted
Weight: 12.00 lbs
Cautions: install vertically or horizontally in a dry, accessible areaconsult factory before drilling metal casekeep covered except during wiring as contactors are sensitive
to debrishi-pot with LPT75CA disconnected or hi-pot on load side of switch
*Additional shipping costs apply.
Includes the following models:
*Additional shipping costs apply.
The ES3030G is intended for usage as an electrical transfer switch to automatically switch from the main power source (i.e. shoreline) to generator power.
Additional shipping costs may apply.
*Additional shipping costs apply.
The ES3030I Is intended for usage as an electrical transfer switch to automatically switch from the main power source (i.e. shoreline) to inverter power.
Additional shipping costs may apply.
*Additional shipping costs apply.
MODEL # ES350 240VAC 50 AMPS/POLE
Automatic Transfer Switch
Automatic switching between shorepower, generator and inverter.
The ES350 is designed to monitor both legs of the generator supply with the generator always being the dominant source. In addition to functioning as a generator time delay (average 30 sec.), the integrated control circuitry monitors the generator supply voltage. Should generator power output drop to 105VAC or less for 5 seconds after the time delay sequence, the control board switches power back to the shore input. If shore power is not available, the ES350 will source inverter power. Once the generator output measures above 105VAC, the ES350 will switch from shore power or inverter power back to generator power.
The ES350 is designed for use with generators having a rated output of 50 Amps at 120/240VAC single phase 60 Hz, an external power source (shore cord) of 50 Amps at 120/240VAC single phase 60 Hz and an AC inverter supplying up to 50 Amps at 120VAC.
PHYSICAL SIZE: 12” x 10” x 6”
KNOCKOUTS: Assorted
WEIGHT: 14 lbs
Cautions:
*Additional shipping costs may apply.
*Additional shipping costs apply.
Models include:
ES50-SURGE, ES50-VOLT-SURGE, ES50CSA-65N, ES50M-65N
The ES50-Volt-Surge (same as ES50-VOLT with Surge Protection)
MODEL # ES50-VOLT-SURGE 240VAC 50 AMPS/POLE
65 AMP NEUTRAL
Is an Automatic Transfer Switch that automatically switches from power cord to generator.
FEATURES:
The ES50-VOLT-SURGE is intended for use as an electrical transfer switch to automatically switch multiple sources (from one to another), i.e. switching from shoreline to generator power.
The ES50-VOLT-SURGE is primarily designed for installation in conjunction with a generator having a rated output no larger than 12KW, an external power cord having a rated output no larger than 2 pole, 240VAC, 50A, 1PH, 60HZ .
CONTACTORS: 3 pole N.O. 240 VAC, 50 Amps/Pole
COIL: 110VAC (60H, Inrush Current - 77 Watts, Sealed - 4.0 Watts)
AUXILIARY SWITCHES: One shoreline and one generator release switch, 120VAC, N.C.
PHYSICAL SIZE: 8” x 9” x 4-7/8”
KNOCKOUTS: Assorted
TIME DELAY: Custom time delay, 30 seconds nominal, generator low voltage monitoring
WEIGHT: 13 lbs
UNIT ALSO AVAILABLE WITHOUT SURGE PROTECTION. WHEN ORDERING, USE PART # ES50-VOLT.
Cautions:
* Additional shipping costs may apply.
ES50M-65N Automatic Transfer Switch Features
The ES50M-65N is intended for use as an electrical transfer switch to automatically switch multiple sources (from one to another), i.e. switching from shoreline to generator power. It is primarily designed for installation in conjunction with a generator having a rated output no larger than 12KW and an external power cord having a rated output no larger than 2 pole, 240VAC, 50A, 1PH, 60HZ.
CONTACTORS: 3 Pole N.O. 240 VAC 50Amps/Pole
PHYSICAL SIZE: 8 1/2" x 8 1/2" x 4 1/2"
COIL: 110VAC (60Hz, Inrush current - 77 Watts, Sealed - 4.0 Watts)
KNOCKOUTS: Assorted
TIME DELAY: Custom time delay, 30 seconds nominal. Includes generator low voltage monitoring
WEIGHT: 8.5 lbs
CAUTIONS: : Install vertically or horizontally in a dry, accessible area. Consult factory before drilling metal case. Keep covered except during wiring as contactors are sensitive to dust and debris. When hi-potting coach, disconnect es50m-65n or hi-pot on load side of switch. This unit has been hi-potted to UL standards at the factory.
Please contact our staff for pricing (574) 264-4156, elkhartsupply@gmail.com
PART NO | DESCRIPTION | QTY |
ES30-COVER | Cover Label | 1 |
ES30-FAULT | 30A Fault current label | 1 |
ES30-INST | Installation instruction label | 1 |
ES30-TORQUE | Torque label | 1 |
ES30AH-1 | ES30 harness no capacitor | 1 |
ES02 | Red jumper harness | 1 |
10BK-6 | 6 wire for ES3030 w/fork | 1 |
10WH-6 | 6 in wire for ES3030 w/fork | 1 |
QB22 | Connector splicer | 1 |
40050 | Hinged box w/spec holes | 1 |
604704A1-12 | Time delay relay | 1 |
20241-83 | 900 Model 30A DPDT 120Vac coil | 1 |
CSA-LABEL | CSA label for 50A & 30A switch | 1 |
ES30BR | Brown harness wire for ES30 | 1 |
Please contact our staff for pricing
(574) 264-4156, elkhartsupply@gmail.com
PART NO |
DESCRIPTION |
QTY |
SPC8X8X4 |
8x8x4 Enclosure w/ Lid (Reflex) |
1 |
20241-83 |
900 model 30A DPDT 120Vac coil |
2 |
ES50-COVER |
ES-50 cover label |
1 |
ES3030G-INST |
Instruction label-generator |
1 |
CSA-LABEL |
CSA label for 50A & 30A switch |
1 |
ES30-TORQUE |
Torque label |
1 |
604704A1-12 |
Time delay relay |
1 |
ES204-14RE |
3 in for ES3030 I and G 14ga |
4 |
10BK/OR-6 |
6 in wire for ES3030 w/ fork |
2 |
10BK/YE-6 |
6 in wire for ES3030 w/ fork |
2 |
10BK-6 |
6 wire for ES3030 w/ fork |
2 |
10WH-6 |
6 in wire for ES3030 w/ fork |
2 |
10WH/OR-6 |
6 in wire for ES3030 w/ fork |
2 |
10WH/YE-6 |
6 in wire for ES3030 w/ fork |
2 |
QB22 |
Connector splicer |
2 |
Please contact our staff for pricing
(574) 264-4156, elkhartsupply@gmail.com
PART NO |
DESCRIPTION |
QTY |
SPC8X8X4 |
8x8x4 Enclosure w/ Lid (Reflex) |
1 |
20241-83 |
900 model 30A DPDT 120Vac coil |
2 |
ES50-COVER |
ES-50 cover label |
1 |
ES3030I-INST |
Instruction label-inverter |
1 |
CSA-LABEL |
CSA label for 50A & 30A switch |
1 |
ES30-TORQUE |
Torque label |
1 |
S8301-1 |
Fuse holder |
1 |
ES204-14RE |
3 in for ES3030 I and G 14ga |
4 |
10BK/OR-6 |
6 in wire for ES3030 w/ fork |
2 |
10BK/YE-6 |
6 in wire for ES3030 w/ fork |
2 |
10BK-6 |
6 wire for ES3030 w/ fork |
2 |
10WH-6 |
6 in wire for ES3030 w/ fork |
2 |
10WH/OR-6 |
6 in wire for ES3030 w/ fork |
2 |
10WH/YE-6 |
6 in wire for ES3030 w/ fork |
2 |
QB22 |
Connector splicer |
2 |
Please contact our staff for pricing
(574) 264-4156, elkhartsupply@gmail.com
PART NO | DESCRIPTION | QTY |
ES350-INST | ES350 installation label | 1 |
ES30-TORQUE | Torque label | 1 |
ES202-14WH/RE | 7 in for ES3030I 14ga | 1 |
ES350-COVER | ES350 cover label | 1 |
S8301-1 | 1p 1/4x1 1/4 glass fuse holder | 1 |
ES50-102BL | 16ga blue wire for 50A switch | 1 |
ES50-102BR | 16ga brown wire for 50A switch | 1 |
ES50-102OR | 16ga orange wire for 50A switch | 1 |
ES101-8BK7-1R | 50A 8ga black power wire | 4 |
ES101-6WH7-1R | 6ga 65A white neutral w/1ring | 2 |
ES101-6WH7-2R | 6ga 65A white neutral | 1 |
83-9591 | Terminal Pak 14-12 female conn. | 2 |
AGC3 | Glass fuse 250V | 1 |
CR355ADY5A | 50A two speed contactor | 1 |
AB12106HCGK-M | 12x10x6 Enclosure w/Lid (Reflex) | 1 |
R0562-A | 50A DPDT relay 120Vac coil | 1 |
10BK-6 | 6in wire for ES3030 w/fork black | 1 |
10WH-6 | 6in wire for ES3030 w/fork white | 1 |
B104-501 | PCB assembly 50A board | 1 |
ES201-14BK | 14ga 12" with 2 forks | 1 |
ES201-14BK/RE | 14ga 8 1/2" for ES3030I 14GA | 1 |
ES204-14RE | 3in for ES3030 I & G 14ga | 2 |
QB22 | Connector splicer | 3 |
Please contact our staff for pricing
(574) 264-4156, elkhartsupply@gmail.com
PART NO |
DESCRIPTION |
QTY |
ES450G-INST |
ES450G installation label |
1 |
ES30-TORQUE |
Torque label |
1 |
ES50-COVER |
ES-50 Cover label |
1 |
ES101-8BK7-1R |
50A 8ga black power wire |
4 |
ES101-6WH7-1R |
6ga 65A white neutral w/1ring |
2 |
ES101-6WH7-2R |
6ga 65A white neutral |
1 |
CR353ADY39APAK |
3 Pole 50A DP contactor |
2 |
B122-501 |
TD Board For ES50M-65N |
1 |
AB12106HCGK-M |
12x10x6 Enclosure w/Lid (Reflex) |
1 |
21082-84 |
Relay 23653-70 900QR-IC |
1 |
21080-84 |
Relay 900QR |
1 |
16BLF-90F-00 |
9" Blue Wire with 2 Fem. Disconn. |
1 |
16BLF-60S8-00 |
6" Blue Wire w/Fem Disc & Spade |
1 |
16BLF-90S8-00 |
9" Blue Wire w/Fem Disc & Spade |
1 |
16BLF-90F-40F |
Dbl Blue Wire - Fem Disc 9" & 4" |
2 |
QN2-8 |
Ground Bar |
1 |
LPT30-TIME |
Time Delay TD 30 |
1 |
PLS-0002 |
Insulator Pan |
1 |
Please contact our staff for pricing
(574) 264-4156, elkhartsupply@gmail.com
PART NO |
DESCRIPTION |
QTY |
SPC8X8X4 1/2 |
50A T/F box black w/ spec holes |
1 |
CR355ADY5A |
50A two speed contactor |
1 |
B104-501 |
PCB assembly 50A board |
1 |
ES50-COVER |
ES-50 cover label |
1 |
ES50-65N-INST |
Installation label for ES50 switch |
1 |
ES30-TORQUE |
Torque label |
1 |
ES50-102BL |
16ga blue wire for 50A switch |
1 |
ES50-102BR |
16ga brown wire for 50A switch |
1 |
ES50-102OR |
16ga orange wire for 50A switch |
1 |
ES101-8BK7-1R |
50A 8ga black power wire |
2 |
ES101-6WH7-2R |
6ga 65A white neutral |
1 |
QN2-6 |
6 hole neutral bar 50A T/F |
1 |
Please contact our staff for pricing
(574) 264-4156, elkhartsupply@gmail.com
PART NO |
DESCRIPTION |
QTY |
SPC8X8X4 1/2 |
50A T/F box black w/ spec holes |
1 |
CR353ADY39APAK |
3 Pole 50A DP contactor |
1 |
B122-501 |
For the ES50M-65N |
1 |
ES50-COVER |
ES-50 cover label |
1 |
ES50M-65N-INST |
Installation label for ES50M switch |
1 |
ES101-8BK7-1R |
50A 8ga black power wire |
2 |
ES101-6WH7-1R |
6ga 65A white neutral 1 ring |
1 |
QN2-6 |
6 hole neutral bar 50A T/F |
1 |
ES30-TORQUE |
Torque label |
1 |
GE-LABEL |
T label for GE ES50M-65N |
1 |
ES50M-65N-LABEL |
Outside label for ES50M-65N |
1 |
CR353AD3BA1 |
40A generator contactor 110/120V |
1 |
Please contact our staff for pricing
(574) 264-4156, elkhartsupply@gmail.com
PART NO |
DESCRIPTION |
QTY |
SPC8X8X4 1/2 |
50A T/F box black w/ spec holes |
1 |
CR353ADY39APAK |
3 Pole 50A DP contactor |
1 |
B222-501-EUROP |
For the ES50M-EUROP |
1 |
ES50-COVER |
ES-50 cover label |
1 |
ES50-65N-INST |
Installation label for ES50 switch |
1 |
ES101-8BK7-1R |
50A 8ga black power wire |
2 |
ES101-6WH7-1R |
6ga 65A white neutral 1 ring |
1 |
QN2-6 |
6 hole neutral bar 50A T/F |
1 |
ES30-TORQUE |
Torque label |
1 |
GE-LABEL |
T label for GE ES50M-65N |
1 |
CR353AD3BA1 |
40A generator contactor 110/120V |
1 |
B55-B31B |
208/240 Volt Coil |
2 |
EUROP-LABEL |
European label for ES50M-Europ |
1 |
Please contact our staff for pricing
(574) 264-4156, elkhartsupply@gmail.com
PART NO |
DESCRIPTION |
QTY |
SPC8X8X4 1/2 |
50A T/F box black w/ spec holes |
1 |
CR355ADY5A |
50A two speed contactor |
1 |
B104-501 |
PCB assembly 50A board |
1 |
ES50-COVER |
ES-50 cover label |
1 |
ES50-65N-INST |
Installation label for ES50 switch |
1 |
ES30-TORQUE |
Torque label |
1 |
ES50-102BL |
16ga blue wire for 50A switch |
1 |
ES50-102BR |
16ga brown wire for 50A switch |
1 |
ES50-102OR |
16ga orange wire for 50A switch |
1 |
ES101-8BK7-1R |
50A 8ga black power wire |
2 |
ES101-6WH7-2R |
6ga 65A white neutral |
1 |
QN2-6 |
6 hole neutral bar 50A T/F |
1 |
LN102 |
802 3/4 locknut |
1 |
32120-1 |
Panel mount surge suppressor |
1 |
WA132 |
Reducer washer 1x3/4 8122 |
2 |
Please contact our staff for pricing
(574) 264-4156, elkhartsupply@gmail.com
PART NO |
DESCRIPTION |
QTY |
SPC8X8X4 1/2 |
50A T/F box black w/ spec holes |
1 |
CR355ADY5A |
50A two speed contactor |
1 |
B108-501 |
ES50-volt solid state board |
1 |
ES50VOLT-COVR |
ES50-volt cover label |
1 |
ES50-65N-INST |
Installation label for ES50 switch |
1 |
ES50-102BL |
16ga blue wire for 50A switch |
1 |
ES50-102BR |
16ga brown wire for 50A switch |
1 |
ES101-8BK7-2R |
50A 8ga black 2 ring for volt |
2 |
ES101-6WH7-2R |
6ga 65A white neutral |
1 |
QN2-8 |
8 hole neutral bar T/F sw |
1 |
ES30-TORQUE |
Torque label |
1 |
Please contact our staff for pricing
(574) 264-4156, elkhartsupply@gmail.com
PART NO |
DESCRIPTION |
QTY |
SPC8X8X4 1/2 |
50A T/F box black w/ spec holes |
1 |
CR355ADY5A |
50A two speed contactor |
1 |
B108-501 |
ES50-volt solid state board |
1 |
ES50VOLT-COVR |
ES50-volt cover label |
1 |
LN102 |
802 3/4 locknut |
1 |
32120-1 |
Panel mount surge suppressor |
1 |
ES50-65N-INST |
Installation label for ES50 switch |
1 |
ES50-102BL |
16ga blue wire for 50A switch |
1 |
ES50-102BR |
16ga brown wire for 50A switch |
1 |
ES101-8BK7-2R |
50A 8ga black 2 ring for volt |
2 |
ES101-6WH7-2R |
6ga 65A white neutral |
1 |
QN2-8 |
8 hole neutral bar T/F sw |
1 |
WA132 |
Reducer washer 1x3/4 8122 |
2 |
ES30-TORQUE |
Torque label |
1 |